Rate of death (more information about the current death rates and replacements is here)
For three plugins disassembled from the detector, we have measured the IV-curves of the laser diode. For a plugin assembled with a BPM chip this can only be done in forward direction.
The result is the same as achieved last year looking at the ESD damages devices:
The dead channel shows a changed IV-characteristic. The knee voltage and the rise of the curve is changed
from the normal behavior.
Description
Measuring the optical spectrum of the devices, it can be seen that the spectrum for used channels
is narrowing.
It is not yet clear, how this develops with time, if it is to be expected, if this is the reason for failures etc.
Further investigations are ongoing.
A typical spectrum can be seen here (for a 12 channel array out of which the
middle eight have been operated).
|
The VCSEL surface has been observed under a microscope. Pictures like the following can be found here.
|